A. Abdo et alii, Frattura ed Integrità Strutturale, 64 (2023) 11-30; DOI: 10.3221/IGF-ESIS.64.02
details were used for the two samples (spacing 150 mm). The last sample was J2-UHPC2-J which used UHPFRC2 at the critical lengths and no stirrups in the joint zone. Fig. 4. shows the dimensions and steel reinforcement details.
(a)
(b)
(c)
(d) (e) Figure 4: Details of joint reinforcements. a) Control connection (RFC), b) Stirrups at 150 mm (RF1), c) No stirrups at the joint core (RF2), d) column cross-section, e) beam cross-section.
The type of Concrete in the Joint
The type of Concrete in the rest of the sample
Stirrups in the joint zone Φ 6 @ 60mm Φ 6 @ 150mm Φ 6 @ 150mm
Sample
RF * details
Control
NC
NC
RFC
J1-NC
NC
NC
RF1 RF1
J1-UHPC
UHPC
UHPC
RF1
Φ 6 @ 150mm
J1-UHPFC1
UHPFRC1
UHPFRC1
RF1
Φ 6 @ 150mm
J1-UHPFC2
UHPFRC2
UHPFRC2
NC
RF1
Φ 6 @ 150mm
J1-UHPC-J
UHPC
NC
RF1
Φ 6 @ 150mm
J1-UHPFC1-J
UHPFRC1
NC
J2-UHPFC2-J
UHPFRC2
RF2
-
Note: *RF: Reinforcing details. Table 3: Details of the exterior BCJ specimens.