Issue 61

R. Andreotti et alii, Frattura ed Integrità Strutturale, 61 (2022) 176-197; DOI: 10.3221/IGF-ESIS.61.12

Figure 31: 5.56x45 mm NATO impact. Maximum cavity width: experimental results (above) compared to simulation seen from the two cross directions (below). Time = 3.0 ms. The resolution of the checkered ruler is 20 mm.

Figure 32: 5.56x45 mm NATO penetration as a function of time. Comparison between experimental results (blue line) and simulation (red line).

Cartridge

Absorbed energy [J] - Experimental

Absorbed energy [J] - Simulation (Error [%])

9x21 mm FMJ round-nose

404.32 1582.45 1617.28

483.88 (+20%) 1763.39 (+11%) 1584.29 (-2%)

7.62x39 mm FMJ 5.56x45 mm NATO

Table 3: Summary of the absorbed energy [J].

195