S. Ahmed et alii, Frattura ed Integrità Strutturale, 60 (2022) 243-264; DOI: 10.3221/IGF-ESIS.60.17
average load of 107.6 kN with a maximum average displacement for the screw was 31.2 mm, as shown in Fig. 18(b). In addition, the failure shape for normal concrete was confined to the existence of the plastic dowel from its position, as shown in Fig. 19. However, the failure shape for UHPC sleepers was a fracture in the concrete, as shown in Fig. 20.
Crack inspection at a load of 60 kN
Sleeper series
Number
Fracture load
SN
No.6 No.7 Avg. No.6 No.7 Avg.
No cracks No cracks
109 kN
116.3 kN 112.6 kN 106.6 kN 108.7 kN 107.6 kN
S0
No cracks No cracks
Table 8: Pull-out test result.
(a)
(b) Figure 18: Load versus screws exit distance pull-out test: (a) SN; (b) S0.