their failure. The difference is that while corner cracks appeared on the surface of the mortar from the beginning of compression, in the case of the socket leveler this was only observed for the first time in the stress range of 12.7-20.75 MPa. During the uniaxial compression tests on the specimens made from ceramic powder, initial cracks suddenly appeared in the stress range of 18.75-33.75 MPa (Fig. 7 d). Small, sudden drops in the stress appeared on each individual stress-strain curve, which is not visible on the averaged curves. The fractures appeared parallel to each other, which indicates that the failure form of the specimen was splitting. This form of failure was not shown by the other investigated materials.

Figure 5: Averaged stress-strain diagram of compression tests on railway ballast materials (The Young’s moduli are indicated).

Figure 6: Averaged stress-strain diagram of compression tests on materials used in construction industry (with indicated Young’s moduli).

218