Issue 55
F. A. Elshazly et al, Frattura ed Integrità Strutturale, 55 (2021) 1-19; DOI: 10.3221/IGF-ESIS.55.01
0 100 200 300 400 500 600 700
0 100 200 300 400 500 600 700 800
(C114*3‐235‐0)‐EXP (C114*3‐235‐0)‐FE
(C114*3‐235‐5)‐EXP (C114*3‐235‐5)‐FE
Axial load (KN)
Axial load (KN)
0
2
4
6
8
10
0
5
10
15
20
Axial shortening (mm)
Axial shortening (mm)
(a)
(b)
0 100 200 300 400 500 600
(C114*3‐235‐15)‐EXP (C114*3‐235‐15)‐FE
Axial load (KN)
0
5
10
15
20
Axial shortening (mm)
(c) (d) Figure 5: Comparison between proposed model and experimental results of Duarte et al. [18]; (a), (b), (c) Load-axial shorteing curves (d) Deformed shape at failure.
Figure 6: Experimental and finite element ultimate load of the twenty simulated CFST columns.
10
Made with FlippingBook - professional solution for displaying marketing and sales documents online