PSI - Issue 54
Anna Karolak et al. / Procedia Structural Integrity 54 (2024) 460–467 Karolak A., Jasieńko J. / Structural Integrity Procedia 00 (2019) 000 – 000
463
4
C
Beam with inclined lap joint created in vertical plane with 4 bolts; the length of the joint – 540 mm (+90 mm both sides); overlap half the width of the beam – 60 mm
D Beam with inclined lap joint created in vertical plane with 2 bolts; the length of the joint – 540 mm (+90 mm both sides); the length of the joint – 540 mm; overlap half the width of the beam – 60 mm
E
Beam with stop- splayed scarf joint (‘bolt of lightning’) created in horizontal plane with 2 bolts; the length of the joint – 540 mm; vertical notches in the lightning sign – 40 mm
F Beam with stop- splayed scarf joint (‘bolt of lightning’) created in horizontal plane with wooden keys 100 mm x 40 mm (made from oak wood) and steel clamps (flat bars and bolts); the length of the joint – 540 mm; vertical notches in the lightning sign – 40 mm
G Beam with stop- splayed scarf joint (‘bolt of lightning’) created in horizontal plane with steel clamps (flat bars and bolts); the length of the joint – 540 mm; vertical notches in the lightning sign – 40 mm
H
Beam with stop- splayed scarf joint (‘bolt of lightning’) created in vertical plane with 4 bolts the length of the joint 540 mm; notches in the lightning sign – 30 mm