Issue 51
C. Ferrero et alii, Frattura ed Integrità Strutturale, 51 (2020) 92-114; DOI: 10.3221/IGF-ESIS.51.08
August 24 th , 2016 (PGAx = 0.33 g)
October 26 th , 2016 (PGAx = 0.36 g)
+X direction
Load factor 0.33 g - Max. principal crack width 1.52 mm
Load factor 0.36 g - Max. principal crack width 1.76 mm
a)
b)
-X direction
Load factor 0.33 g - Max. principal crack width 1.58 mm
Load factor 0.37 g - Max. principal crack width 1.93 mm
c) d) Figure 16: Principal crack width for horizontal load factors comparable to the PGA recorded in the X direction of the building in the seismic events of August 24 th , 2016 (left) and October 26 th , 2016 (right): a)-b) +X direction, c)-d) -X direction.
August 24 th , 2016 (PGAy = 0.32 g)
October 26 th , 2016 (PGAy = 0.47 g)
+Y direction
Load factor 0.32 g - Max. principal crack width 2.07 mm
Load factor 0.42 g - Max. principal crack width 8.51 mm
b)
a)
-Y direction
Load factor 0.32 g - Max. principal crack width 1.70 mm
Load factor 0.44 g - Max. principal crack width 7.29 mm
c) d) Figure 17: Principal crack width for horizontal load factors comparable to the PGA recorded in the Y direction of the building in the seismic events of August 24 th , 2016 (left) and October 26 th , 2016 (right): a)-b) +Y direction, c)-d) -Y direction.
108
Made with FlippingBook - professional solution for displaying marketing and sales documents online