Issue 50
N. Alexopoulos et alii, Frattura ed Integrità Strutturale, 50 (2019) 342-353; DOI: 10.3221/IGF-ESIS.50.29
2 hours
reference
reference
500
500
1 hour
stress drop
0.5 hours
6 hours
168 hours
4 hours
400
400
720 hours
8 hours
100 Nominal axial stress σ [MPa] 200 300
2184 hours
12 hours
4200 hours
300
24 hours
200
100
Aluminum alloy 2024- T3 t= 3.20 mm, L direction Exposure at 3.5 % NaCl solution
Aluminum alloy 2024-Τ3 t = 3.2 mm, L direction Exposure at EXCO solution
Nominal axial stress σ [MPa]
0
0
0.00
0.05
0.10
0.15
0.20
0.00
0.05
0.10
0.15
0.20
(a)
(b)
Nominal axial strain ε [-]
Nominal axial strain ε [-]
500
reference
0.10 mm
0.15 mm
400
0.30 mm
100 Nominal axial stress σ [MPa] 200 300 0.50 mm
AA2024-T3 L, t = 3,2 mm with artificial surace-notches
0
0.00
0.05
0.10
0.15
0.20
(c) Figure 3: Typical tensile nominal stress - strain curves of AA2024-T3 after corrosion exposure for different exposure times to (a) EXCO solution, (b) 3.5 wt. % NaCl solution and (c) varying depth of artificial surface notches. Nominal axial strain ε [-]
(a)
(b)
(c)
(d) (f) Figure 4: Typical photographs of AA2024-T3 pre-corroded tensile specimens exposed to the EXCO solution (a)-(c) for 2 h, 4 h and 24 h, respectively and 3.5 wt. % NaCl solution (d)-(f) for 6 h, 168 h and 720 h, respectively. (e)
346
Made with FlippingBook Online newsletter