Issue 50

F. Jafari et alii, Frattura ed Integrità Strutturale, 50 (2019) 209-230; DOI: 10.3221/IGF-ESIS.50.18

Fig. 12 shows that the displacement in the insulating layer having low density and height has the lowest displacement in the frame. According to Fig. 12, the insulating layer displacement on the right side of the panel is approximately similar. On the left, increasing the number of sandwich panels increases the frame displacement measure.

Figure 12 : The polystyrene panel displacement (a) on the right side, b) on the left side).

Figure 13 : The acceleration on the left side of the concrete layers (a) sample 1 and 2, b) sample 2&3).

Figure 14 : The acceleration on the left side of the concrete layers (a) sample 1 and 2, b) sample 2&3).