Hachimi Taoufik et al. / Procedia Structural Integrity 47 (2023) 711 – 722 Author name / Structural Integrity Procedia 00 (2019) 000 – 000

718

8

Fig. 8. ImageJ: Calculation of Crack length.

Fig.9 shows the propagation of the initial crack in different frames. At each moment in time, we measure the current length of the crack and the proportion of the frame's expected lifespan that has been exhausted. By analyzing the variation in the crack's length over time, we can gain insights into the structure's performance and identify potential areas for improvement. In this way, our methodology allows us to continually monitor the frame's health and make informed decisions about maintenance and repair.

a ≃ 5mm

a ≃ 7mm

a ≃ 9.5mm a ≃ 14.5mm

a ≃ 16.5mm

Fig. 9. Monitoring Crack Propagation in Different Frames: A Performance Analysis.

Made with FlippingBook Digital Proposal Maker