PSI - Issue 47

Andre Hartawan Mettanadi et al. / Procedia Structural Integrity 47 (2023) 168–175 Mettanadi et al. / Structural Integrity Procedia 00 (2019) 000 – 000

172

5

Table 1. Material properties of Aluminum 6061-T4. Material Properties

Units

Value

Density

Tonne / mm 3

2.7

Poisson’s ratio Young’s Modulus Initial Yield Stress Ultimate Stress Shear Modulus Shear strength Thermal Conductivity

-

0.28

GPa MPa MPa GPa MPa W/m.K

70 112.14 214.16

260 170 170

Figure 5. Stress - strain relation of Aluminum 6061 - T4 material.

3.4. Benchmark profile

Based on a study conducted by Liang et al. (2022) on the design of a new bionic bamboo tube for several compression load cases, the FE model was verified using a Universal testing machine. The test specimen is named as “BBT - 1” as shown in Figure 6. Axial compression experiment of the Aluminum 6061 -T4 cylinder tube was tested by a universal testing machine with a measurement range of 300 kN at room temperature. Then, the testing machine processes holes in the specimen by cutting the wire to process the inner cavity of the BBT-1 structure. Then, with computer programming, the wire-cutting process was carried out to complete the processing of the BBT-1 specimen. The BBT-1 specimen is placed on a rigid plate and compressed by the plate at a compression rate of 5 mm/min. The results taken from this study as material for validation are the hysterical results from testing BBT-1 specimens using a universal testing machine.

Figure 6. Compression test for BBT-1 by Liang et al. (2022).

Made with FlippingBook Annual report maker