Issue 43
D. Gentile, Frattura ed Integrità Strutturale, 43 (2018) 155-170; DOI: 10.3221/IGF-ESIS.43.12
Fig. 19 shows the G II values (max min and average) calculated at maximum load. It is possible to note that the material L1 and T1000-3 give a shorter dispersion data. For these materials bridging occurs less time that the others materials.
Figure 16 . Summary of strain energy release rates for tested materials.
0.7
G
I =0.52533-0.04285*t
0.6
0.5
0.4
I [kJ/m 2 ]
0.3
G
0.2
0.1
0.0
2
3
4
5
6
7
8
9 10
Thickness [mm] Figure 17. Average strain energy release vs specimen thickness.
Figure 18 . Bridging in a DCB specimen.
168
Made with FlippingBook - Online Brochure Maker