Issue 30
A. MartÃn-Meizoso et alii, Frattura ed Integrità Strutturale, 30 (2014) 14-22; DOI: 10.3221/IGF-ESIS.30.03
Figure 6 : Necking and fracture of a mini-tensile probe.
1200
1200
1000
1000
800
800
600
600
400
400
200 Engineering STRESS (MPa)
Engineering STRESS (MPa)
200
0
-2000 -1500 -1000 -500 0
0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2 0
0.05 0.1 0.15 0.2
0
Mid-Distance from Flame cut (microns)
Engineering STRAIN
Engineering STRAIN
Figure 7 : Evolution of engineering stress vs. engineering strain as a function of distance from oxy-fuel cut edge, for the upper locations of cut edge (2.5 mm below upper plate surface).
1200
1200
1000
1000
800
800
600
600
400
400
200 Engineering STRESS (MPa)
Engineering STRESS (MPa)
200
0
-2000 -1500 -1000 -500 0
0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2 0
0.05 0.1 0.15 0.2
0
Mid-Distance from Flame cut (microns)
Engineering STRAIN
Engineering STRAIN
Figure 8 : Evolution of engineering stress vs. engineering strain as a function of distance from oxy-fuel cut edge, for middle thickness location of cut edge.
19