Issue 30
A. Risitano et alii, Frattura ed Integrità Strutturale, 30 (2014) 201-210; DOI: 10.3221/IGF-ESIS.30.26
the temperature analysis, the measurements were carried out for the three types of specimens (smooth and notched) on the temperature values measured at the centre of the specimen (see Fig. 11). The collected data are the same reported in the above mentioned diagrams.
Density
g/cm 3
7.87 163 810 725 210 0.29
Brinell Hardness Ultimate Stress
[MPa] [MPa] [GPa]
Yield Stress
Young Modulus Poisson Modulus Ultimate Elongation
% [J]
16 30
Resilience (Izod)
Thermal Conductivity
[W/m*K]
51.9
Specific Heat
[J/g*K]
0.502
Coefficient of linear expansion
[1E-06/K] [Ohm*cm]
15.1
Electrical Resistivity
1.42E-05
Table 2 : Physical and mechanical properties.
Sorge Specimens
Autocorrelation
“eye estimated”
AISI 1045-P1 SMOOTH (12.5x5) AISI 1045-P2 SMOOTH (12.5x5) AISI 1045-P3 NOTCHED (10.9x5) AISI 1045-P4 NOTCHED (10.9x5) AISI 1045-P5 NOTCHED (8.3x5) AISI 1045-P6 NOTCHED (8.3x5)
164.5 168.9 183.2 275.1 264.7 212.6
172.0 170.0 175.0 225.0 250.0
195.0 Table 3 : Values of the detected stresses referred to the 6 (P1-P6) specimens.
Figure 1 : Qualitative stress-strain ( ) curve and Temperature-strain ( T- ) curve of a static monoaxial traction test (indication of 0 ).
205
Made with FlippingBook - professional solution for displaying marketing and sales documents online