Numan Berat Yondu et al. / Procedia Structural Integrity 42 (2022) 1567–1575 Author n me / Structural Integrity Procedia 00 (2019) 000 – 00

Figure7. Microstructural imaging of fracture surfaces a) 450 o C Dwell Fatigue test 598Mpa 1.14 normalized cycles to failure b) 450 o C Dwell Fatigue test 598Mpa 1.11 normalized cycles to failure c) Macro monitoring of a.

TASNİF DIŞI

Figure8. SEM imaging of fracture surfaces a) 450 o C Fatigue test 771Mpa 0.91 normalized cycles to failure b) 450 o C Dwell Fatigue test 771Mpa 0.96 normalized cycles to failure.