Crack Paths 2012
Changeof Electrical Potential during Fatigue
The change in the electrical potential under cyclic shear stress amplitude of 180MPain
case A for SUSis shown in Fig. 3(a), where the electrical potential was normalized by
the initial value. The number of stress cycles at point where the electrical potential
shows a rapid increase is considered to indicate crack initiation. It is interesting to note
that N C specimen shows the earliest rise in the electrical potential, followed by N B
specimen and N Aspecimen. The crack initiation life is shorter as the notch gets sharper.
Figure 3(a) Change of electrical potential during fatigue of SUS316Lin case A.
Figure 3(b) Change of electrical potential during fatigue of SGV410in case A.
34